Home > Masonry fastenings > Masonry façade fastenings > Accessories and versions > DB/GH/HB/GB/TA: Lintel ties for invisible support
Lintel ties for invisible support
Accessories and versions DB/GH/HB/GB/TA
Accessories and versions DB/GH/HB/GB/TA
Use and application
- Distance between ties in brick lintels <25 cm, in prefabricated lintels in accordance with structural requirement.
- Appropriate retention, such as longitudinal reinforcement or formation of mortar pockets, must be provided in brick lintels and in cases with poor adhesion between mortar and facing brick.
- It is essential to ensure that the supporting structure under brick lintels is fully supported until the brick mortar has set hard.


Accessories and versions DB/GH/HB/GB/TA
View tables
| Type / Version | Bracket height | Strecher H= 7,1 cm | Brick-on-edge H= 11,5 cm | Soldier H= 24 cm | 1½-fold Soldier H= 36 cm | Width of facing brick | Use |
|---|---|---|---|---|---|---|---|
|
| 20 | - | 80 | 180 | 310 | 115 | WK-D WK-N WK-E WK-K WK-O WK-M WK-Z WA-Ü WA-Z |
| 30 | |||||||
| 40 | |||||||
| 50 | |||||||
| 60 | |||||||
| 70 | |||||||
| 80 | |||||||
| 90 | |||||||
|
| - | < 115 | |||||
|
| - | 40 | - | - | - | ||
|
| - | - | 80 | 180 | 310 | 115 | EK-U |
| Bracket height for angle-bracket anchors normally = 60 mm. | |||||||
| Type/ Version | Use | |||
|---|---|---|---|---|
|
| M8 (H=180 mm) | M10 (H=180 mm) | M12 (H=180 mm) |
FB-U |
|
| 28/15-150 | 38/17-150 | 50/31-150 | |
| Other dimensions on request | ||||
| Thema |
|---|
| Technical regulation governing masonry support (DIN 1053) |
| Principles for dimensioning masonry support |
Errata and technical changes reserved.
Accessories and versions DB/GH/HB/GB/TA