Adjustable
Angle-bracket anchor WK-D
Your advantages at a glance:
- Design perfected through practical experience ... Type WKD ... the perfect adjustment range facilitates compensation for dimensional tolerances
- The adjustable pressure strut is easy to move yet securely attached to the masonry bracket, thus enabling full-surface contact to the bearing surface, even in the case of slightly sloping substrates
- Wall clearances greater than 200 mm are also possible for increased thermal insulation. As well as our MOSO support brackets, we will also obtain specific approval for our air gap wire anchor based on DIN 1053
- We also supply the matching, approved air gap wire anchors at low cost

View tables
| Type / Version | Load stage | 3,5 kN/back | 7,0 kN/back | 10,5 kN/back | |||
|---|---|---|---|---|---|---|---|
| Distance/wall | Cantilever length K | Bracket height x | Cantilever length K | Bracket height x | Cantilever length K | Bracket height x | |
|
| 20 - 50 | 130 | 150 | 130 | 200 | 130 | 250 |
| 40 - 70 | 150 | 150 | 150 | 200 | 150 | 250 | |
| 60 - 90 | 170 | 150 | 170 | 200 | 170 | 250 | |
| 80 - 110 | 190 | 150 | 190 | 200 | 190 | 250 | |
| 100 - 130 | 210 | 150 | 210 | 200 | 210 | 250 | |
| 120 - 150 | 230 | 175 | 230 | 250 | 230 | 300 | |
| 140 - 170 | 250 | 175 | 250 | 250 | 250 | 300 | |
| 160 - 190 | 270 | 175 | 270 | 250 | 270 | 300 | |
| 180 - 200 | 290 | 175 | 290 | 250 | 290 | 300 | |
| Wall clearances greater than 200 mm available on request | |||||||
| Bracket width | W | 100 | 100 | 100 | |||
| Bracket length | L | up to 4000 | up to 4000 | up to 4000 | |||
| Max. size of fastener | up to M12 | up to M12 | up to M16 | ||||
| Shear connector for uncracked concrete ≥ C20/25 (compression zone) | UPAT UKA3 M10x165 | UPAT UKA3 M12x190 | UPAT UKA3 M16x215 | ||||
| Shear connector for cracked | Fischer FHB II-AS M10x60/60 | Fischer FHB II-AS M12x75/60 | Fischer FHB II-AS M16x95/60 | ||||
| HK-screw on supporting anchor rail in concrete ≥ C20/25 | MHK 38/17 M12x80 | MHK 50/30 M12x80 | MHK 50/30 M16x100 | ||||
| Values apply for facing bricks 115 mm thick with a superimposed load < 2 storeys, otherwise the anchors must be adapted in accordance with DIN 1053. Other dimensions on request | |||||||
| Superimposed | Load | Bracket length, | Load stage | Arrangement | |
|---|---|---|---|---|---|
| < 1,50 | < 3,105 | 2000 mm/2R | 3,5 | 500 / 1000 / 500 | |
| < 2,00 | < 4,140 | 1500 mm/2R | 3,5 | 250 / 1000 / 250 | |
| < 3,00 | < 6,210 | 1750 mm/2R | 7,0 | 375 / 1000 / 375 | |
| < 4,50 | < 9,315 | 1500 mm/2R | 7,0 | 375 / 750 / 375 | |
| < 6,00 | < 12,420 | 1000 mm/2R | 7,0 | 250 / 500 / 250 | |
| < 9,00 | < 18,630 | 1000 mm/2R | 10,5 | 250 / 500 / 250 | |
| < 12,00 | < 24,840 | 750 mm/2R | 10,5 | 187,5 / 375 / 187,5 | |
| (Assuming a 115 mm wide facing brick with γ=18kN/m³. | |||||
| Subject |
|---|
| Individual evidence of attachment in the anchorage base:
|
| Abutments for suspended facework: |
| Installation instructions: |