For masonry as the base of the laying work
Angle-bracket anchor WK-M
The MOSO angle-bracket anchor type WK-M is set into the masonry.
This type of anchor is preferably used whenever the substrate for anchorage does not permit the use of dowels.
In order to minimize the effort involved in installation, the anchors can be individually dimensioned by our engineering office.
Your advantages at a glance:
- Due to its large bearing surfaces and high stability as a projecting fastening element, this anchor is ideal for the renovation of old buildings
- Wall clearances greater than 200 mm are also possible for increased thermal insulation. As well as our MOSO support brackets, we will also obtain specific approval for our air gap wire anchor based on DIN 1053
- We also supply the matching, approved air gap wire anchors at low cost

View tables
| Type / AVersion | Load stage | 3,5 kN/back | 7,0 kN/back | ||||
|---|---|---|---|---|---|---|---|
| Distance/wall | Cantilever length K | Bracket height x | Cantilever length K | Bracket height x | Cantilever length K | Bracket height x | |
|
| 20 - 50 | 130 | 50 | ≥ Ø80x200 | 130 | 50 | ≥ Ø160x200 |
| 40 - 70 | 150 | 50 | ≥ Ø90x200 | 150 | 50 | ≥ Ø170x200 | |
| 60 - 90 | 170 | 50 | ≥ Ø100x200 | 170 | 50 | ≥ Ø190x200 | |
| 80 - 110 | 190 | 50 | ≥ Ø120x200 | 190 | 50 | ≥ Ø200x200 | |
| 100 - 130 | 210 | 50 | ≥ Ø120x200 | 210 | 50 | ≥ Ø210x200 | |
| 120 - 150 | 230 | 50 | ≥ Ø120x200 | 230 | 50 | ≥ Ø230x200 | |
| 140 - 170 | 250 | 50 | ≥ Ø120x200 | 250 | 50 | ≥ Ø250x200 | |
| 160 - 190 | 270 | 50 | ≥ Ø140x200 | 270 | 60 | ≥ Ø270x200 | |
| 180 - 200 | 290 | 50 | ≥ Ø140x200 | 290 | 60 | ≥ Ø300x200 | |
| Wall clearances greater than 200 mm available on request | |||||||
| Bracket width | W | 100 | 100 | ||||
| Bracket length | L | up to 4000 | up to 4000 | ||||
| Attachment in mortar | Expanding mortar MG III | Expanding mortar MG III | |||||
| Attachment in concrete | ≥ C12/15 | ≥ C12/15 | |||||
| Values apply for facing bricks 115 mm thick with a superimposed load < 2 storeys, otherwise the anchors must be adapted in accordance with DIN 1053. Other dimensions on request | |||||||
| Superimposed | Load | Bracket length, | Load stage | Arrangement | |
|---|---|---|---|---|---|
| < 1,50 | < 3,105 | 2000mm/2R | 3,5 | 500 / 1000 / 500 | |
| < 2,00 | < 4,140 | 1500 mm/2R | 3,5 | 250 / 1000 / 250 | |
| < 3,00 | < 6,210 | 1750 mm/2R | 7,0 | 375 / 1000 / 375 | |
| < 4,50 | < 9,315 | 1500 mm/2R | 7,0 | 250 / 1000 / 250 | |
| < 6,00 | < 12,420 | 1000 mm/2R | 7,0 | 250 / 500 / 250 | |
| (Assuming a 115 mm wide facing brick with γ=18kN/m³. Note individual evidence of attachment!) | |||||
| Subject |
|---|
| Abutments for suspended facework: |