Home > Masonry fastenings > Masonry façade fastenings > MOSO perforated strip > Lintel reinforcement: Variant specification
Variant specification
MOSO perforated strip Lintel reinforcement
- • Use of the MOSO perforated strip effectivel reinforces the brick lintel and makes it self-supporting.• The lintel can be produced as either a soldier course or a brick-on-edge course.• Perforated binders and re-anchoring binders are also installed to ensure a secure connection between the brickwork (see detail).• MOSO perforated strip is officially approved for use in lintels in frostresistant masonry work in accordance with DIN 1053-1 using bricks in accordance with DIN 105-1 and DIN 105-2.Use of the MOSO perforated strip effectivel reinforces the brick lintel and makes it self-supporting.
- The lintel can be produced as either a soldier course or a brick-on-edge course.
- Perforated binders and re-anchoring binders are also installed to ensure a secure connection between the brickwork (see detail).
- MOSO perforated strip is officially approved for use in lintels in frostresistant masonry work in accordance with DIN 1053-1 using bricks in accordance with DIN 105-1 and DIN 105-2.
Your advantages at a glance:
- Convenient packaging
- Simple installation, in accordance with common masonry practice
- No need to prepare cage reinforcement, and no complicated insertion of bricks from the side
- We have a wide range of standard perforated strip fastenings in stock for all common lintel heights,. For intermediate heights, the length of the fastenings can simply be adjusted
MOSO perforated strip Lintel reinforcement
View tables
| Table of material required per lintel *1) | Maximum width of opening IW (m) | |||||||
|---|---|---|---|---|---|---|---|---|
| ≤ 1,01 | ≤ 1,26 | ≤ 1,51 | ≤ 1,76 | ≤ 2,01 | ≤ 2,26 | ≤ 2,51 | ||
| Number of perforated strip layers | with h0 ≥ 0,42 m *2) | 1 | 1 | 1 | 1 | 1 | 1 | 2 |
| with h0 ≥ 0,75 m *2) | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
| Cut perforated strip length (m) | 1,73 | 1,98 | 2,23 | 2,48 | 2,73 | 2,98 | 3,23 | |
| Number of perforated binders (LB..) | 4 | 5 | 6 | 7 | 8 | 9 | 10 | |
| Number of re-anchoring binders (RVB) | 6 | 7 | 8 | 9 | 10 | |||
| *1) On-site pinning for brick-on-edge and soldier courses must be included additionally *2) h0 equals the height of masonry above the perforated strip layer. The minimum masonry height equals five layers normal format (NF) 42 cm. | ||||||||
*1) On-site pinning for brick-on-edge and soldier courses must be included additionally
*2) h0 equals the height of masonry above the perforated strip layer.
The minimum masonry height equals five layers normal format (NF) 42 cm.
Errata and technical changes reserved.