Home  > Masonry fastenings > Masonry façade fastenings > Scaffold anchors > GA-Q/GA-Z: Scaffold anchors for masonry facades

Scaffold anchors for masonry facades

Scaffold anchors GA-Q/GA-Z

Anchorage with MOSO scaffold anchor type GA-Q.

Scaffold must be secured in accordance with DIN 4420.

The MOSO scaffold anchor type GA-Z only transmits tensile loads, while the type GA-Q anchor ensures that transverse forces are also reliably transmitted into the anchorage bas.

Scaffold anchors GA-Q/GA-Z

Product information

  • Load stages:
  • Distance from the wall:
  • Material:
  • Evidence:

3,3 - 8,0 kN
50 - 200 mm

approved stainless steel
structural analysis

Scaffold anchors GA-Q/GA-Z

Use and application

  • Type GA-Q for tensile and transverse forces, also for anchorage in cracked concrete.
  • Type GA-ZZ for tensile forces only, also for anchorage in cracked concret
  •  Type GA-ZD for tensile only, for anchorage in uncracked concrete
Scaffold anchors GA-Q/GA-Z

View tables

Technical data

Type / Version

Load stage

 

3,3 kN (GA-Q)

5,0 kN (GA-ZZ)

5,0kN (GA-ZD)

8,0 kN (GA-Q)

Distance/wall

Cantilever length K

Width W

Length L

Length L

Width W

50 - 60

155

120

155

265

155

60 - 70

165

130

165

275

165

70 - 80

175

136

175

285

175

80 - 90

185

143

185

295

185

90 - 100

195

150

195

305

195

100 - 110

205

156

205

315

205

110 - 120

215

163

215

325

215

120 - 130

225

170

225

335

225

130 - 140

235

177

235

345

235

140 - 150

245

184

245

355

245

150 - 160

255

191

255

365

255

160 - 170

265

198

265

375

265

170 - 180

275

205

275

385

275

180 - 190

285

212

285

395

285

190 - 200

295

219

295

405

295

Required eyebolt

M12

M12

M12

M12

Protective plug

grey Ø 20 mm

grey Ø 20 mm

grey Ø 20 mm

grey Ø 20 mm

Max. size of fastener

up to M12

up to M12

up to M12

up to M12

Shear connector for uncracked concrete
> C20/25 (Compression zone)

UPAT UKA3
M10x130

UPAT UKA3
EAP M12

UPAT UKA3
M12x160

Shear connector for cracked concrete
> C20/25 (Tension/Compression zone)

Fischer
FHB ll-AS
M10x60/20

Fischer
FHB ll-AS
M12x75/25

-

Fischer
FHB ll-AS
M12x75/25

Walues apply for facing bricks 115 mm thick, load stage = permissible tensile force F I in accordance with DIN 4420, Part 3.

Other dimensions on request

Permissible transverse force

Type

Load stage

Permissible transverse
force F II

GA-Q

3,3 kN

1,2 kN

GA-ZZ

5,0 kN

0 kN

GA-ZD

5,0 kN

0 kN

GA-Q

8,0 kN

0,9 kN

Transverse force F II in accordance with DIN 4420, Part 3.
Cross-reference for additional information

Subject

Individual evidence of attachment in the anchorage base:

Technical regulation for scaffold anchorage (DIN 4420)

Principles for dimensioning masonry support

Errata and technical changes reserved.
Scaffold anchors GA-Q/GA-Z

Technical drawings

MOSO scaffold anchor type GA-Q.
MOSO scaffold anchor type GA-Q, top view.
Type GA-ZD.
Type GA-ZD, top view.
Type GA-ZZ, top view.