For soldier-course lintels with low masonry height
Single-bracket anchors EK-G
Your advantages at a glance:
- Constant stock of standard sizes for fast delivery
- Very simple installation
- Cost-effective version for smaller load ranges
- Wall clearances greater than 200 mm are also possible for increased thermal insulation. As well as our MOSO support brackets, we will obtain specific approval for our air gap wire anchor based on DIN 1053
- We also supply the matching, approved air gap wire anchors at low cost
Use and application
- • For invisibly supporting lintels with low masonry height.• Can also be used near corners and edges.• When using frost-resistant bricks with poor mortar bonding, the bricks should be pinned additionally.• Choice of single-bracket anchors is not dependent on the length of lintel.• Single-bracket anchors set at intervals of ak = 25 cm.For invisibly supporting lintels with low masonry height.
- Can also be used near corners and edges.
- When using frost-resistant bricks with poor mortar bonding, the bricks should be pinned additionally.
- Choice of single-bracket anchors is not dependent on the length of lintel.
- Single-bracket anchors set at intervals of ak = 25 cm.
View tables
| Type / Version | Load stage | 0,3 kN | 0,8 kN | ||
|---|---|---|---|---|---|
| Distance/wall | Cantilever length K | Bracket height x | Cantilever length K | Bracket height x | |
|
| 10 - 30 | 95 | 55 | 95 | 55 |
| 30 - 50 | 115 | 55 | 115 | 55 | |
| 50 - 70 | 135 | 65 | 135 | 65 | |
| 70 - 90 | 155 | 75 | 155 | 75 | |
| 90 - 110 | 175 | 85 | 175 | 85 | |
| 110 - 130 | 195 | 95 | 195 | 95 | |
| 130 - 150 | 215 | 105 | 215 | 105 | |
| 150 - 170 | 235 | 125 | 235 | 125 | |
| 170 - 190 | 255 | 135 | 255 | 135 | |
| 190 - 200 | 275 | 145 | 275 | 145 | |
| Wall clearances greater than 200 mm available on request | |||||
| Length of restraint | L | 180 | 180 | ||
| Max. size of fastener | up to M10 | up to M10 | |||
| Attachment | Fischer SXR 10x60 FUS | Fischer FAZ M10/10 | |||
| Values apply for facing briks 115 mm thick with a superimposed load < 2 storeys, otherwise the anchors must be adapted in accordance with DIN 1053 Other dimensions on request | |||||
| Superimposed | Load(kN/m) | Anchor spacing | Load stage |
|---|---|---|---|
| < 0,67 | < 1,387 | 0,25 | 0,3 |
| < 1,50 | < 3,105 | 0,25 | 0,8 |
| (Assuming a 115 mm wide facing brick with γ=18kN/m³. Note individual evidence of attachment.) | |||
| Subject |
|---|
| Individual evidence of attachment in the anchorage base:
|