With longer support
Single-bracket anchors EK-L
Your advantages at a glance:
- Constant stock of standard sizes for fast delivery
- Very simple installation
- Height-adjustable
- Wall clearances greater than 200 mm are also possible for increased thermal insulation. As well as our MOSO support brackets, we will also obtain specific approval for our air gap wire anchor based on DIN 1053
- We also supply the matching, approved air gap wire anchors at low cost
Use and application
- • Particularly suitable for invisibly supporting large wall surfaces.• Can also be used near corners and edges if outer and inner walls are closely spaced.• Fixed anchor spacing aK = 50 cm (2bricks).• The brackets must be fully supported until the brick mortar has set hard.Particularly suitable for invisibly supporting large wall surfaces.
- Can also be used near corners and edges if outer and inner walls are closely spaced.
- Fixed anchor spacing aK = 50 cm (2bricks).
- The brackets must be fully supported until the brick mortar has set hard.

View tables
| Type / Version | Load stage | 3,5 kN | 7,0 kN | 10,5 kN | |||
|---|---|---|---|---|---|---|---|
| Distance/wall | Cantilever length K | Bracket height x | Cantilever length K | Bracket height x | Cantilever length K | Bracket height x | |
|
| 20 - 50 | 130 | 150 | 130 | 200 | 130 | 250 |
| 40 - 70 | 150 | 150 | 150 | 200 | 150 | 250 | |
| 60 - 90 | 170 | 150 | 170 | 200 | 170 | 250 | |
| 80 - 110 | 190 | 150 | 190 | 200 | 190 | 250 | |
| 100 - 130 | 210 | 150 | 210 | 200 | 210 | 250 | |
| 120 - 150 | 230 | 175 | 230 | 250 | 230 | 300 | |
| 140 - 170 | 250 | 175 | 250 | 250 | 250 | 300 | |
| 160 - 190 | 270 | 175 | 270 | 250 | 270 | 300 | |
| 180 - 200 | 290 | 175 | 290 | 250 | 290 | 300 | |
| Wall clearances greater than 200 mm available on request | |||||||
| Supporting bracket | W / H / B...L | 100/40/3...300 | 100/60/3...300 | 100/60/4...300 | |||
| Max. size of fastener | up to M12 | up to M12 | up to M16 | ||||
| Shear connector for uncracked | UPAT UKA3 M10x165 | UPAT UKA3 M12x190 | UPAT UKA3 M16x215 | ||||
| Shear connector for cracked | Fischer FHB II-AS M10x60/60 | Fischer FHB II-AS M12x75/60 | Fischer FHB II-AS M16x95/60 | ||||
| HK screw on supporting anchor | MHK 38/17 M12x80 | MHK 50/30 M12x80 | MHK 50/30 M16x100 | ||||
| Values apply for facing bricks 115 mm thick with a superimposed load < 2 storeys, otherwise the anchor must be adapted in accordance with DIN 1053 Other dimensions on request | |||||||
| Superimposed Load(m) | Load (kN/m) | Load stage | ||
|---|---|---|---|---|
| < 1,50 | < 3,105 | 3,5 | ||
| < 2,00 | < 4,140 | 3,5 | ||
| < 3,00 | < 6,210 | 3,5 | ||
| < 4,50 | < 9,315 | 7,0 | ||
| < 6,00 | < 12,420 | 7,0 | ||
| < 9,00 | < 18,630 | 10,5 | ||
| (Assuming a 115 mm wide facing brick with γ=18kN/m³. Note individual evidence of attachment!) | ||||
| Subject |
|---|
| Individual evidence of attachment in the anchorage base:
|
| Installation instructions for MOSO supporting anchors: |