For retroactive anchorage in the masonry
Single-bracket anchors EK-M
Your advantages at a glance:
- Constant stock of standard sizes for fast delivery
- Slim design prevents the need for costly and laborious chiselling and drilling
- Ideal for softer substrates, particularly during façade refurbishments
- Wall clearances greater than 200 mm are also possible for increased thermal insulation. As well as our MOSO support brackets, we will also obtain specific approval for our air gap wire anchor based on DIN 1053
- Matching, approved air gap wire anchors included in delivery
Use and application
- • For retroactive invisible support for wall sufaces.• Variable anchor spacing (ak) at 25 cm intervals, depending on load.• Cannot be used near corners and edges.• Install anchors at intervals ak and loosely fit intermediate brackets type WA-Z in between if necessary.• The brackets must be fully supported until the brick mortar has set hard.For retroactive invisible support for wall sufaces.
- Variable anchor spacing (ak) at 25 cm intervals, depending on load.
- Cannot be used near corners and edges.
- Install anchors at intervals ak and loosely fit intermediate brackets type WA-Z in between if necessary.
- The brackets must be fully supported until the brick mortar has set hard.

View tables
| Type / Version | Load stage | 3,5 kN | 7,0 kN | ||
|---|---|---|---|---|---|
| Distance/wall | Cantilever length K | Bracket height x | Cantilever length K | Bracket height | |
|
| 20 - 50 | 130 | 72 | 130 | 91 |
| 40 - 70 | 150 | 72 | 150 | 91 | |
| 60 - 90 | 170 | 72 | 170 | 91 | |
| 80 - 110 | 190 | 80 | 190 | 101 | |
| 100 - 130 | 210 | 80 | 210 | 101 | |
| 120 - 150 | 230 | 87 | 230 | 106 | |
| 140 - 170 | 250 | 87 | 250 | 106 | |
| 160 - 190 | 270 | 87 | 270 | 106 | |
| 180 - 200 | 290 | 87 | 290 | 106 | |
| Wall clearances greater than 200 mm available on request | |||||
| Supporting bracket | W / H / B...L | 80/60/3 | 80/60/4 | ||
| Core hole or recess | ≥ Ø 140 x 200 | ≥ Ø 250 x 220 | |||
| Attachment in mortar | Expanding mortar MG III | Expanding mortar MG III | |||
| Attachment in concrete | ≥ C12/15 | ≥ C12/15 | |||
| Values apply for facing bricks 115 mm thick with a superimposed load < 2 storeys, otherwise the anchor must be adapted in accordance with DIN 1053 Other dimensions on request | |||||
| Superimposed | Load (kN/m) | Anchor spacing ak (m) | Load stage | Intermediate bracket |
|---|---|---|---|---|
| < 1,50 | < 3,105 | 1,00 | 3,5 | WA-Z-95/50/3-980 |
| < 2,00 | < 4,140 | 0,75 | 3,5 | WA-Z-95/30/3-730 |
| < 3,00 | < 6,210 | 1,00 | 7,0 | WA-Z-95/50/3-980 |
| < 4,50 | < 9,315 | 0,75 | 7,0 | WA-Z-95/30/3-730 |
| < 6,00 | < 12,420 | 0,50 | 7,0 | WA-Z-95/20/2-480 |
| (Assuming a 115 mm wide facing brick with γ=18kN/m³. | ||||
| Subject |
|---|